Pro-Dent CT mk II

01-501

The new Pro-Dent CT mk II phantom is a versatile quality control tool of dental Cone-Beam CT, Dental Volume Tomography (DVT) and other 3D imaging devices according to the Radiation Protection Report no 172 by SEDENTEXCT.

The phantom consists of a main PMMA cylinder that houses modules with different test objects. Thanks to this design, you can perform tests with devices with a small FOV at different positions in the 160 mm phantom.

Technical data (can be modified to customer specifications):

General

  • diameter: 160 mm
  • made of PMMA (1.19 g/cm³)
  • total length: 170 mm
  • positioning aids on the outside surface of the phantom

Noise / uniformity section

  • uniform PMMA part of the phantom

A transparent acrylic round plate with a sanded and printed top surface.

5 layer modules section with modules containing

  • Linear Spread Function (LSF) PTFE / PMMA interface
  • Point Spread Function (PSF) - 0.25 mm tungsten steel wire in air
  • XY high contrast resolution (aluminum/polymer) - 1.0, 1.7, 2.0, 2.5, 2.8, 4.0, 5.0 LP/mm
  • Z high contrast resolution (aluminum/polymer) - 1.0, 1.7, 2.0, 2.5, 2.8, 4.0, 5.0 LP/mm
  • 6 low-contrast groups of 1.0, 2.0, 3.0, 4.0, 5.0, 6.0 mm rods made of: aluminum, PTFE, POM-C (delrin), PE-300, air and water emulating epoxy; background made of PMMA
  • 10 mm rods made of aluminum, PTFE, POM-C (delrin), PE-300, air and water emulating epoxy suspended in PMMA - pixel intensity / HU values samples
  • stacked 20 mm diameter contrast-to-noise discs made of aluminum, PTFE, POM-C (delrin), PE-300 and air suspended in PMMA
  • three 5.0 mm diameter titanium rods embedded in PMMA - beam hardening artefacts

5 acrylic transparent plates stacked one above the other with white triangular inserts with bevelled corners, and printed top surface.

Slice geometry section

  • 20 mm thick module with two pairs of aluminum ramps and empty rods in vertexes of a square for detailed evaluation of slice thickness and geometry and laser position verification

A transparent acrylic round plate with two pairs of aluminium ramps and empty rods in vertexes of a square.

Geometric distortion section

  • an array of 2.0 mm diameter, 3.0 mm long holes uniformly pitched at 10.0 mm intervals

A transparent acrylic round plate with an array of shallow holes uniformly pitched at 10 mm intervals.

Accessories:

  • test stand with spirit level for accurate placing of the phantom in the test position
  • folding base for test stand positioning on the X-ray unit’s chair
  • convenient, portable case for storing and transporting the phantom
  • optional additional homogeneity disc

Product features:

  • complies with:
    – Radiation Protection no 172 report by the SEDENTEXCT
    – IEC 61223-3-4 and IEC 61223-3-5
  • CE certified
  • the manual provides detailed guidelines for carrying out each test, results assessment and registration

Ask a Distributor for an offer

Locate a local distributor and access exclusive medical offers tailored to your needs.

Share this product
Close Cookie Preference Manager
Cookie Settings
By clicking “Accept All Cookies”, you agree to the storing of cookies on your device to enhance site navigation, analyze site usage and assist in our marketing efforts. More info
Strictly Necessary (Always Active)
Cookies required to enable basic website functionality.
Made by Flinch 77
Oops! Something went wrong while submitting the form.